Smoke Detector Trouble Conditions
There are several different models of Smoke Detectors. If yours is not listed below, please refer
to the
Peripheral Device Manual
Ademco Honeywell 5806 W3
These Trouble Conditions apply to the
5806W3
wireless smoke detector. This smoke detector has 2
LEDs and a sounder to indicate the detector's status.
State
Green LED
Normal
Blinks every
(standby)
10 seconds
Smoke Alarm
Off
Thermal
Off
o
Alarm (>135
)
Freeze
Off
Trouble
o
(<41
)
Smoke & Heat Detector Troubleshooting
page to locate the user's manual for your device.
Ademco Honeywell
Red LED
Sounder
Off
Off
Blinks every
Pattern
1 second
Blinks every
Pattern
4 seconds
Blinks every
Off
10 seconds
Action
The device is operating normally. No
action needed.
Smoke has been detected. ADT has
been contacted. Press the recessed
test switch to silence the smoke
detector sounder for 5 minutes. If
necessary, silence the alarm keypad.
Remove the source of the smoke, if it
can be done safely. If necessary, fan
the smoke detector for a few minutes
to further dissipate any smoke or
particles. If the device still indicates a
problem, it may be necessary to clean
it. Please refer to Caring for Your
Smoke Detector below.
The unit has detected that the
temperature is above 135
o
been contacted. Press the recessed
test switch to silence the smoke
detector sounder for 5 minutes. If
necessary, silence the alarm keypad.
Remove the source of the heat, if it
can be done safely.
The unit has detected that the
o
temperature is below 41
F, which
could lead to a freeze situation within
the premises. Investigate the cause
and resolve.
F. ADT has
Page 1 of 8

Advertisement

loading

Summary of Contents for Honeywell Ademco 5806 W3

  • Page 1 There are several different models of Smoke Detectors. If yours is not listed below, please refer page to locate the user’s manual for your device. to the Peripheral Device Manual Ademco Honeywell 5806 W3 These Trouble Conditions apply to the Ademco Honeywell 5806W3 wireless smoke detector.
  • Page 2 State Green LED Red LED Sounder Action Low Battery Blinks every The battery power is low. ADT has 0-7 days 45 seconds been contacted. You will be notified of the non-emergency situation. Replace the battery. Please refer to the Smoke and Heat Detector Battery Replacement page.
  • Page 3 State Sounder Alarm Mode Action Smoke Alarm Blinks every Pattern or In Alarm Smoke has been detected. ADT second Steady has been contacted. Press the test switch to silence the smoke detector sounder for 5 minutes. If necessary, silence the alarm keypad.
  • Page 4: Testing The Smoke Detector

    State Sounder Alarm Mode Action Tamper Blinks every Tamper An attempt has been made to 50 seconds remove the Smoke Detector, causing the Tamper switch to be depressed. ADT has been contacted. You will be notified of the non-emergency situation. Take appropriate precautions or replace the smoke detector properly.
  • Page 5: How They Work

    Alarm Mode on Action State Keypad Normal None The device is operating normally. No action needed. (standby) Alarm - Heat Alarm for Heat Heat in excess of 135 F OR an increase in temperature in excess Detector Zone of 15 F per minute has been detected.
  • Page 6 Dust and other particles will collect on the smoke detector over time. Cleaning the smoke detector every 3-6 months will help to avoid false alarms. The following cleaning steps refer to the wireless Ademco Honeywell model 5806W3. Further information is available in the Ademco Honeywell 5803W3 device manual.
  • Page 7 4. Wait at least 20 seconds to ensure proper power-down sequence. 5. Remove the detector cover by turning counter-clockwise. 6. Vacuum the cover or use canned air to remove any dust or debris. 7. Remove the top half of the screen/sensing chamber by lifting straight up. 8.
  • Page 8: Related Topics

    A heat detector employing a Rate of Rise threshold will activate if the temperature rises 15 more per minute. If an alarm temperature threshold is available, it is usually set at 135 or 194 An alarm will be triggered if any threshold is exceeded. Due to the design of the heat detection mechanism, once an alarm has been triggered, the heat detector must be replaced.