Resetting Gas Alarm Setpoints - Honeywell GasAlertMicro 5 User Manual

Gas detector
Table of Contents

Advertisement

GasAlertMicro 5/PID/IR
User Manual
The time/date, TWA, STEL, low, and high alarm setpoint screens display
in the following order left to right:.
If a correction factor has been applied to a sensor, one of the following
screens display indicating the sensor and gas type.
42

Resetting Gas Alarm Setpoints

Standard factory alarm setpoints may vary by region.
The following table lists the factory alarm setpoints according to the
Occupational Safety and Health Association (OSHA) settings.
Table 10. OSHA Sample Factory Alarm Setpoints
Gas
TWA
O
N/A
N/A
2
LEL
N/A
N/A
CO
35 ppm
50 ppm
H
S
10 ppm
15 ppm
2
PH
0.3 ppm
1.0 ppm
3
SO
2 ppm
5 ppm
2
Cl
0.5 ppm
1.0 ppm
2
NH
25 ppm
35 ppm
3
NO
2.0 ppm
5.0 ppm
2
HCN
4.7 ppm
10.0 ppm
ClO
0.1 ppm
0.3 ppm
2
O
0.1 ppm
0.1 ppm
3
VOC
50 ppm
100 ppm
5,000
30,000
CO
2
ppm
ppm
Note
STEL
Low
19.5% vol.
23.5% vol.
10% LEL
20% LEL
35 ppm
200 ppm
10 ppm
15 ppm
0.3 ppm
1.0 ppm
2 ppm
5 ppm
0.5 ppm
1.0 ppm
25 ppm
50 ppm
2.0 ppm
5.0 ppm
4.7 ppm
10.0 ppm
0.1 ppm
0.3 ppm
0.1 ppm
0.1 ppm
50 ppm
100 ppm
5,000
30,000
ppm
ppm
High

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gasalertmicro 5pidGasalertmicro 5ir

Table of Contents