Free Bound Virtualized Storage When The Master System Fails; All Cifs Connections Were Unexpectedly Ended - Cisco NSS2000 - Gigabit Storage System Chassis Administration Manual

Cisco nss2000 series network storage system administration guide
Hide thumbs Also See for NSS2000 - Gigabit Storage System Chassis:
Table of Contents

Advertisement

Troubleshooting

Free Bound Virtualized Storage when the Master System Fails

STEP 2
Free Bound Virtualized Storage when the Master System Fails
STEP 1
STEP 2
STEP 3
STEP 4
STEP 1
STEP 2

All CIFS Connections were Unexpectedly Ended

Cisco Small Business NSS2000 Series Administration Guide
Go through the steps to upgrade the firmware ensuring that the conditions listed
previously are met.
Problem Scenario: A storage system is bound to a failed storage system and
rejects any bind requests from other systems. The steps to recreate this problem
are as follows:
Export storage from System A.
Import storage from System A to System B.
System B crashes and cannot be recovered.
System A is "bound" to System B and rejects any new bind requests from other
systems.
Resolution: To resolve the problem:
Unexport the bound storage system (in our example, System A).
Re-export the storage system.
The storage system is now available to be used by another system.
Problem: All current CIFS connections to the NSS were unexpectedly severed.
Solution: Check if the hostname set up in the Network Identification page has been
changed. Changing the hostname severs any current CIFS connections to the NSS.