Codabar

<Default All Codabar Settings>
Codabar
* On
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters.
Default = Don't Transmit .
Transmit
* Don't Transmit
Codabar Check Character
Codabar check characters are created using different "modulos." You can pro-
gram the imager to read only Codabar barcodes with Modulo 16 check charac-
ters. Default = No Check Character.
No Check Character indicates that the imager reads and transmits barcode
data with or without a check character.
When Check Character is set to Validate and Transmit, the imager will only
read Codabar barcodes printed with a check character, and will transmit this
character at the end of the scanned data.