Interfunction Delay - Honeywell 4600RSF051CE User Manual

Commercial/retail/industrial area imager
Table of Contents

Advertisement

Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value
for the ASCII character that will trigger the delay
ASCII Conversion Chart (Code
Page
1252), page A-4.
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length barcode, and set the number of
steps to 0. Scan the Save barcode using the
Programming Chart
inside the
back cover of this manual.

Interfunction Delay

An interfunction delay of up to 495 milliseconds (in 5 ms steps) may be placed
between the transmission of each segment of the message string. Scan the
Interfunction Delay barcode below, then scan the number of 5 millisecond
steps (0-99), and the Save barcode using the
Programming Chart
inside the
back cover of this manual.
Prefix
Scanned Data
Suffix
STX
1
HT
2 3 4 5
CR
LF
Interfunction Delays
Interfunction Delay
To remove this delay, scan the Interfunction Delay barcode, then set the num-
ber of steps to 0. Scan the Save barcode using the
Programming Chart
inside
the back cover of this manual.
4 - 6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents