An intermessage delay of up to 495 milliseconds (in 5 ms steps) may be placed
between each scan transmission. Scan the Intermessage Delay barcode
below, then scan the number of 5 millisecond steps (0-99), and the Save bar-
code using the
Programming Chart
inside the back cover of this manual.
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay barcode, then set the num-
ber of steps to 0. Scan the Save barcode using the
Programming Chart
inside
the back cover of this manual.