Low Power Time-Out Timer
Scan the Low Power Time-Out barcode to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the
inside back cover, and Save. Default = 120 seconds.
If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.
Note: This time-out does not begin until the imager time-out setting has expired.
Programming Low Power Time-Out in the secondary interface also
programs it in the primary interface.

Hands Free Time-Out

The Automatic Trigger and Presentation Modes are referred to as "hands free"
modes. If the imager's trigger is pulled when using a hands free mode, the
imager changes to manual trigger mode. You can set the time the imager
should remain in manual trigger mode by setting the Hands Free Time-Out.
Once the time-out value is reached, (if there have been no further trigger pulls)
the imager reverts to the original hands free mode.
Note: If you change the time-out duration for the secondary interface, the
duration of the primary interface will also be changed.
Scan the Hands Free Time-Out barcode, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000
ms.
Low Power Time-Out
Hands Free Time-Out
6 - 7