Honeywell Envitec AlcoQuant 6020 plus Operating Instructions Manual page 32

Table of Contents

Advertisement

AlcoQuant 6020 plus
Phase
Display on
device
Switching on Error
Calibration
Measurement Error sound
Return to menu
Measurement Error
Sampling
system
Measurement Residual
concen-tration
too high
Measurement Blow-in error
Measurement Error
Sampling
system
Measurement Error
Temperature
32
Result
LED signals Cause/solution
Confirm
RED
with key
Error
RED,
sound
remains on
permanently
Return to
menu
or RED
flashes
Error
RED
sound
Return to
menu
Automati
RED
cally
returns to
measure
ment
readines
s
No
RED
measure
ment
value is
displayed
No
YELLOW
measure
ment
value is
displayed
Device must be recalibrated.
No measurements are possible.
Contact service.
Errors prevent measurement
readiness.
No measurements are possible.
Contact service.
The sampling system cannot be
set into initial position.
Replace batteries; if problem
persists the device is faulty.
Contact service.
High concentration of alcohol
from previous measurement or
alcohol residue and moisture in
the blow-in tract.
Wait for a few minutes.
Blow through/dry the device with
a new mouthpiece.
Replace mouthpiece after every
measurement.
Blow-in was too strong or too
weak. Blow into the device
slowly and constantly until the
acoustic beep stops.
Sampling system not in nominal
position after measurement.
Hold the device still during the
sampling system and analysis.
Replace batteries; if problem
persists the device is faulty.
Contact service.
The device temperature was not
within the permitted range at the
time of analysis.
Doc no.: 059-07-1001779_A6020plus_GB-5.2.1 / 12.2021