Honeywell Notifier INSPIRE E10 Installation Instructions Manual page 18

Fire alarm control panels
Hide thumbs Also See for Notifier INSPIRE E10:
Table of Contents

Advertisement

Panel Technical Data
ELECTRICAL
The Panel's power supply equipment (PSE) provide power requirements of the local display and fitted modules
and their external circuits. In addition, the panel contains a battery charger circuit for the mains-fail, back-up
batteries. All the power is normally derived from an external AC mains power source. When the mains power
supply is not available, the standby batteries automatically supply the power requirements for a limited period,
this period being determined by the requirements of the local fire standards.
Mains Voltage: 230 V AC Voltage Tolerance: -15%, +10% (195.5 V to 253 V) at 50 - 60 Hz ±6%
Incoming Mains Fuse (F1): T3.15 AS 250 V (5x20 mm HRC anti-surge fuse in the Mains terminal block)
Mains Input Current: 1.15 A for the 240 W PSU and 2.3 A for the 480 W PSU
Battery Charger Output Voltage: 27.2 V nominal at 20°C (temperature compensated and current limited)
Power Supply Output Rating: 36 V, 6.7 A for 240 W PSU and 36 V, 13.3 A for 480 W PSU.
Standby Batteries YUASA NP range: minimum 12 Ah for E10 enclosure, 24 Ah for both E10/ E15 enclosures
and maximum 38 Ah battery is E15 enclosure, (2 x 12 V DC sealed lead- acid required).
Operating Voltage for the CIE's line: 30 V (DC / DC converted -> independent from PSE status
Operating Voltage range for the CIE's output: 24 V ± 5 % DC, same at every Module
Maximum Current drawn from the battery by the PSE when the main power source is disconnected:
11,5 A (@ 240 W PSU) 23 A (@ 480 W PSU)
Battery circuit in-line fuse (F2): 25 A