Zenith HydroTap G5 Installation Instructions Manual

Zenith HydroTap G5 Installation Instructions Manual

Command centre
Hide thumbs Also See for HydroTap G5:

Advertisement

Quick Links

Installation Instructions
Zenith
HydroTap G5
Command Centre - UltraCare
BCU40, BCU60, BCU100
AFFIX PRODUCT LABEL HERE
Visit our website to
download the manuals
807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions
1

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HydroTap G5

  • Page 1 Installation Instructions Zenith HydroTap G5 Command Centre - UltraCare BCU40, BCU60, BCU100 AFFIX PRODUCT LABEL HERE Visit our website to download the manuals 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 2: Table Of Contents

    Enjoy filtered boiling and chilled water from the Zenith HydroTap. Zenith HydroTap UltraCare adds anti-bacterial components and an ultraviolet module to eliminate bacteria and other micro-organisms. Due to the process of continuous improvement, Zenith reserves the right to change details mentioned in this manual, without notice. Visit www.zenithwater.co.nz...
  • Page 3: Section 1: Using These Instructions

    Read and use the instructions supplied with individual kit components for a safe installation. Explanation of symbols Read the WARNING Danger of Hot surface Highly instructions electric shock Flammable Button/ coin battery 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 4: Section 2: Important Safety Instructions

    R290 (UK & EU markets), or R134a (all other markets) refrigerant under pressure. Check the rating plate or contact Zenith before commencing work. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician.
  • Page 5 5 C when the system is not in use, do not turn off the Command º Centre electrically. This safeguard does not offer the same protection to the connecting pipework and fittings. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 6: Section 3: Warnings & Regulatory Information

    • The Zenith HydroTap must be earthed. Earthing is provided via the supplied power cord. The resistance of the earth connection to each exposed metal part must be less than 1Ω. Use the power cable supplied.
  • Page 7 The power cord and general power outlet must be in a safe and accessible position after installation. When positioning the appliance, ensure the power supply cord is not trapped or damaged. If the power supply cord is damaged it must be replaced by a Zenith service provider or a qualified electrician. •...
  • Page 8: Section 4: Technical Data

    Note: All models (excluding UK) have an internal pressure limiting device to reduce the maximum mains regulated pressure (700kPa in Australia), protecting the system against pressure surges above 500kPa. Water supply connection 1/2” BSP (G1/2). 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 9 The system is only designed to reduce normally occurring non-pathogenic nuisance microorganisms. Class B systems are not intended for treatment of contaminated water. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 10 *Figures above show the capacity of the power supply under full load. Less will be drawn when used with the UV-C module Booster specification Specification Rating Power 230V 50/60Hz 2.20kW Power 240V 50/60Hz 2.40kW Flow rate 1.2 L/min 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 11: Section 5: Parts Supplied & Tools Required

    Font Font kit Optional Note: Mains water isolation valve is not supplied with the kit. Contact Zenith for the full range of consumables and accessories. Tools In addition to standard tools, the following special tools will be required for installation: •...
  • Page 12: Section 6: General Layout

    Mains water supply (isolation Command Centre valve not supplied) Command Centre mains HydroTap power cable Exhaust duct UV-C module power supply Optional Booster mains Vent tray power cable UV-C module 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 13: Section 7: Set Up The Ventilation

    HydroTap system. Command Centre width If cupboard temperature exceeds 35°C, additional ventilation is required. Contact your Zenith service provider for options (including additional vents and fan kit). 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 14 4mm door buffers (supplied) Vent tray Vent tray exhaust cut-out Vent tray dimensions WxDxH (mm): 500 x (515-555) x 40 Absolute min. vent tray depth 490mm (limit of travel, may affect airflow). 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 15: Section 8: Connect The Water Supply

    Mixer Tap to connect the water supply if using the mixer tap option. Note correct strainer orientation. Male - Female Isolation valve adaptor (not supplied) Strainer (supplied) (supplied) Connect to Command Centre, see page 20 Connect together Connect to Command Centre, see page 20 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 16: Section 9: Set The Bypass & Install The Limescale Filter

    For filter head and scale filter installation use the guide supplied with the filter head and filter respectively. Water Water Bypass in Bypass out see page 20 see page 20 Insert Remove Insert Bypass valve (Rear of the Command Centre) Remove 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 17: Section 10: Fit The Booster

    • Supplied with selected models, or available as an optional accessory. Booster 10⁰ 15⁰ Note Take care not to break the clips when removing or installing the Booster. Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 18: Section 11: Connect The Booster

    Command Centre connect to Command Centre BYPASS OUT BYPASS IN see page 20 see page 20 Strainer 3/8" BSP connections Hold connections with spanner Booster while tightening hoses Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 19: Section 12: Connect The Command Centre

    Take care when positioning before cutting and make a clean cut straight across the hose, using a sharp blade. • The hoses must not be under tension when installed. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 20 BC res check USB position MAINS MIXER MIXER BOILING BYPASS VENT BYPASS CHILLED OUTLET Optional booster and limescale filter B res comm MAINS MIXER MIXER BOILING BYPASS VENT BYPASS 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 21 • Connect the UV-C power supply to the power outlet • Ensure the self adhesive L-shaped bracket (supplied) is fitted in position, this will Self adhesive protect the power supply from L-shaped bracket accidental disconnection. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 22: Section 13: Commissioning

    • Touch the back arrow to go back to previous menu. English • In the previous menu, touch the arrow to Imperial Units : Metric begin the commissioning process. Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 23 • Note This selection will determine if water is dispensed automatically or requires operation of the tap during the tank flush process. • Touch the arrow to continue. Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 24 • Once the filter flush is finished, close the stop cock valve . • Wipe up any spills. • Close the door to secure the appliance. Stop cock valve closed Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 25 This can take up to 10 minutes. BOILING CALIBRATION 12:12 Boiling Water Temp. Water tank is filing 88.0 °C Safety Steam Vent Temp. 80.0 °C Element Power % Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 26 • Pull both tap levers to the forward position. • Turn the power on. • The safety sensor will calibrate. • Return the levers to the neutral position. Quick Start Installation Guide 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 27: Troubleshooting

    Troubleshooting The HydroTap tap lights will flash to indicate when service is required. Refer to the LCD screen in the Command Centre. Call your local Zenith service provider for assistance, service, spare parts or enquiries. System fault message Possible cause...
  • Page 28 UV PCB is faulty UV Comms Error Communication b. Ribbon cable connecting No communication restored. the UV PCB and the LCD to the UV IO PCB. PCB is faulty. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 29: Operation & Maintenance

    HydroTap. The User Guide is located in the HydroTap Command Centre filter door. Zenith offers a fully-inclusive HydroCare Service Plan to take care of all routine maintenance, including filter replacements, sanitisation, electrical safety inspections as well as general maintenance of your HydroTap. For more...
  • Page 30: Cleaning

    Failure to remove the cleaning liquid may damage the finish of the tap. Touch-Free Wave Tap • Do not use abrasives to clean the sensor lenses at the sides, top and rear of the tap. • This could cause permanent malfunction and void warranty. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 31: Performance Data Sheet

    Class B systems are not intended for the disinfection of contaminated water. While testing was performed under standard laboratory conditions,actual performance may vary. General UV-C module installation instructions See pages 19-21. 807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions...
  • Page 32 WMKA00099 AS 3498 As Zenith policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. The terms “Zenith” and “HydroTap” are registered trade marks of Zenith Heaters Ltd.