Zenith HydroTap Installation Instructions Manual

Cs & csha commercial
Hide thumbs Also See for HydroTap:

Advertisement

Quick Links

Installation Instructions
Zenith HydroTap
®
Filtered, Chilled and Sparkling drinking water for commercial kitchens and tea rooms.
CS & CSHA Commercial
Affix Model Number Label
Here
804050NZ
804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HydroTap

  • Page 1 Installation Instructions Zenith HydroTap ® Filtered, Chilled and Sparkling drinking water for commercial kitchens and tea rooms. CS & CSHA Commercial Affix Model Number Label Here 804050NZ 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 1 of 20...
  • Page 2 Tap options The HydroTap appliance series offers a range of interchangeable taps to suit the customer’s needs (See options below). For ease of installation, it is recommended to fit the tap before installing the undersink unit. The installation procedure for each of the taps is detailed in a separate tap installation instruction book No.
  • Page 3: Table Of Contents

    5.1- CO Purge ........................18 5.2- Filter Flush ......................... 18-19 Trouble Shooting Trouble Shooting Table ........................ 19 End of life disposal ........................19 Contact details ..........................20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 3 of 20...
  • Page 4: Installation Checklist

    Installation checklist Thank you for purchasing a Zenith HydroTap. Please read and follow these instructions carefully to ensure safe and trouble free service. If service is required, please call 0800 558055 Before Installation: Read the instructions and check if there is adequate space to mount all of the components.
  • Page 5: Important Safety Instructions

    Ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area. Lifting Take care when lifting the Zenith HydroTap unit. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging.
  • Page 6: Warnings And Regulatory Information

    See section 4 for details. WARNINGS The Zenith HydroTap unit must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm. All Installation and service work must be completed by trained and suitably qualified Tradespeople.
  • Page 7: Major Components And Accessories

    1 x Front vent grill 1 x Tee piece for Celsius model 1 x User guide and Guide 1 x Quick start guide 1 off gas cylinder & regulator assy 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 7 of 20...
  • Page 8: Technical Specification

    • Nut runner tube spanner (supplied) for fixing Classic & Elite tap assemblies. • 42mmAF Tube spanner or wrench (Not supplied) for fixing the Celsius & Arc/Cube Tap assemblies Page 8 of 20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01...
  • Page 9: Before Installation And Site Requirements

    • Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation Instructions. Refer to technical specifications and section 4, for Installation instructions. • For Zenith HydroTap CS & CSHA models, a 220-240Vac, 10A GPO will be required. Note Note: Check all cable and hose lengths against inlet /outlet positions before pro- ceeding .
  • Page 10: Section 2 - Ventilation

    Standard ventilation for Chilled Sparkling models. Typical Cut out arrangement for Chilled Sparkling models with kickboard venting via a left hand appliance duct Air inlet vent **MIN. 100mm Page 10 of 20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01...
  • Page 11: Alternative Ventilation

    If the kick board vent kit cannot be used then it is important to fit a standard HydroTap vent kit, which ensures heat dissipation through natural convection via installed vents. For high use applications, where the cupboard space temperature is near 35°C, or higher, an auxiliary ventilation kit must be fitted.
  • Page 12: Section 3 - Co Cylinder And Regulator 3.1 - Connect, Secure And Test The Co2 Gas Cylinder

    Connect the gas hose: Connect the braided gas hose to the threaded end to the regulator (Do not lose the small sealing olive). Page 12 of 20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01...
  • Page 13: Step

    • Flush the supply line before fitting to the undersink unit. • Install the mains water braided hoses to the undersink unit before locating the unit in place. 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 13 of 20...
  • Page 14: Co Regulator

    This olive is necessary to ensure a gas tight seal between the braided hose and the regulator. Pressure regulating knob Page 14 of 20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01...
  • Page 15: Connect The Gas Hose To The Undersink Unit

    If any bubbles appear, the joint will need to be resealed. Installation and connection Installation and connection • Install the undersink unit with the connections shown below 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 15 of 20...
  • Page 16: Chilled Sparkling Models Cs175

    Note: The tube lengths are matched to the pumps performance and therefore CANNOT be lengthened. Take time to consider hose lengths when determining the mounting positions for the options Page 16 of 20 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01...
  • Page 17: Celsius Chilled Sparkling Model Csha175

    - Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap, within reach of the hose and cord lengths supplied 336 mm 804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 Page 17 of 20...
  • Page 18: Section 5 - Commissioning

    Have a 10L bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the Filter Flush Mode is in operation. Open the filter access door on the front of the HydroTap and the filter cartridge will be exposed.
  • Page 19: Trouble Shooting

    Commissioning OPEN Position Stop cock operation CLOSED Position NOTE: For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user guide, located inside the fi lter housing access door. Trouble Shooting System Fault Possible Cause...
  • Page 20: Contact Details

    The standard cup referred to in this publication is 167 ml (6 fl oz). The standard glass is 200 ml (7 fl oz). The terms “Zenith” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. Zenith products described in this publication are manufactured under one or more of the following patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, US5099825 and SA2006/08043.

Table of Contents