Zenith HydroTap G5 Quick Start Installation Manual

Command centre boiling, boiling / ambient models
Hide thumbs Also See for HydroTap G5:

Advertisement

Quick Links

uick Start Installation Guide
Q
Zenith
HydroTap G5
Command Centre
Boiling, Boiling / Ambient models
AFFIX PRODUCT LABEL HERE
Visit our website to
download the manuals
Quick Start Installation Guide
1
806836NZ v1.00 01.21 G5 B BA Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HydroTap G5

  • Page 1 Start Installation Guide Zenith HydroTap G5 Command Centre Boiling, Boiling / Ambient models AFFIX PRODUCT LABEL HERE Visit our website to download the manuals Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...
  • Page 2: Table Of Contents

    Table of contents SECTION 1: Using these instructions ..............3 SECTION 2: IMPORTANT SAFETY INSTRUCTIONS ..........4 SECTION 3: WARNINGS & REGULATORY INFORMATION ........6 SECTION 4: Technical data ................8 SECTION 5: Parts supplied ................. 9 SECTION 6: Set up the ventilation ..............10 SECTION 7: Connect the water supply .............
  • Page 3: Section 1: Using These Instructions

    SECTION 1: Using these instructions Before you start This document is a Quick Start Installation Guide. For further details on installing and operating your HydroTap, download & read the Command Centre installation and user instructions, which can be found online zenithwater.co.nz Read and use the instructions supplied with individual kit components for a safe installation.
  • Page 4: Section 2: Important Safety Instructions

    SECTION 2: IMPORTANT SAFETY INSTRUCTIONS Compliance In NZ/Australia electrical installation must comply with AS/NZS3000. In NZ/Australia plumbing installation must comply with AS/NZS3500. In the UK the system must be installed in accordance with water supply byelaws, current IEE regulations and local authority byelaws. Safety This appliance is not intended for use by children under 8 years or persons (including children under 8 years) with reduced physical, sensory or mental...
  • Page 5 SECTION 2: IMPORTANT SAFETY INSTRUCTIONS Airflow The Zenith HydroTap operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation must be provided. The system will operate satisfactorily only if the recommended air gaps are provided. The vent kit supplied must be fitted.
  • Page 6: Section 3: Warnings & Regulatory Information

    • Connect only to a potable (wholesome, cat1) mains water supply. • Never locate the system near, or clean with water jets. • Do not expose the Zenith HydroTap to the elements of nature. • The booster complies with protection class IP 20.
  • Page 7 When positioning the appliance, ensure the power supply cord is not trapped or damaged. If the power supply cord is damaged it must be replaced by a Zenith service provider or a qualified electrician. • Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
  • Page 8: Section 4: Technical Data

    SECTION 4: Technical data Power rating Dimensions Weight Component W x D x H (mm) (kg) B100, BA100 1.8 + 2.2* 280 x 313 x 333 B60, BA60 280 x 313 x 335 B, BA Home 1.35 280 x 313 x 335 * power rating of the booster Electricity supply requirements 220-240V 50Hz AC (for power requirement see table above).
  • Page 9: Section 5: Parts Supplied

    Optional Font Font kit Optional Optional Note: Mains water isolation valve is not supplied with the kit. Contact Zenith for the full range of consumables and accessories. Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...
  • Page 10: Section 6: Set Up The Ventilation

    SECTION 6: Set up the ventilation A clearance envelope around all Command Centres must be provided to allow ventilation for the safe and effective use of the HydroTap system. Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...
  • Page 11 Air inlet Inlet vent All models If cupboard temperature exceeds 35°C, additional ventilation is required. Contact your Zenith service provider for options (including additional vents and fan kit). Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...
  • Page 12: Section 7: Connect The Water Supply

    SECTION 7: Connect the water supply Valves and fittings must be sealed with PTFE tape if compression seals are not included. Note Mixer tap installations also use a ‘Tee piece’ as part of the water supply plumbing connections, see the Tap installation instructions supplied with the Mixer Tap to connect the water supply if using the mixer tap option.
  • Page 13: Section 8: Set The Bypass & Install The Limescale Filter

    SECTION 8: Set the bypass & install the Limescale filter Available as optional accessory - UK only. For filter head installation use the guide supplied with the filter head. For Limescale filter installation use the guide supplied with the filter. Flush filter before use.
  • Page 14: Section 9: Fit The Booster

    SECTION 9: Fit the Booster • Supplied with selected models, or available as an optional accessory. Booster 10⁰ 15⁰ Note Take care not to break the clips when removing or installing the Booster. Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...
  • Page 15: Section 10: Connect The Booster

    SECTION 10: Connect the Booster Booster Do not connect to electrical power until commissioning. Do not over tighten hose connections. Braided hoses supplied cannot be lengthened. Cold water into Booster, Hot water out of Booster, connect to Command Centre connect to Command Centre BYPASS OUT BYPASS IN see page 17,18...
  • Page 16: Section 11: Connect The Command Centre

    SECTION 11: Connect the Command Centre Generic installation instructions For HydroTap, mixer tap and any optional accessories, use instructions supplied with individual kit components. Mains power cable Braided hose HydroTap Command Connections key Do not connect to the mains Centre socket until commissioning Installation diagrams are for illustrative purposes only.
  • Page 17 MIXER BOILING BYPASS VENT BYPASS BYPASS OUTLET SECTION 11: Connect the Command Centre B60, B100, B Home models Booster (selected models) and BC res limescale filter (optional) Zenith Vented Mixer Tap check Mains connections positi Water MAINS MIXER MIXER BOILING...
  • Page 18 BYPASS VENT BYPASS OUTLET OUTLET B Res Comm SECTION 11: Connect the Command Centre BA60, BA100, BA Home models BCS res Booster (selected models) and limescale filter (optional) Zenith Vented Mixer Tap MAINS MIXER MIXER BOILING BYPASS VENT BYPASS Mains...
  • Page 19: Section 12: Commissioning

    SECTION 12: Commissioning User Guide Unpack, moisten Boiling calibration o-rings & fit filter Filter flush Boost enable Connect electricity if Booster fitted Power off Monitor display screen Flush 10 Litres through Pull levers forward Power on TANK FLUSH 12:12 PM Follow the prompts to flush fresh water through the tank/s 3 times as shown by the cycle counter/s.
  • Page 20 Refer to User Guide for operation and maintenance. Zenith Heaters Limited IRD/GST No. 95 640 729 18 Kawakawa Place, Westgate, Auckland 0814 New Zealand Ph: +(64 9) 838 8612 | Free Call 0800 558 055 zenithwater.co.nz WMKA00099 AU02691 AS 3498 Quick Start Installation Guide 806836NZ v1.00 01.21 G5 B BA Quick Start Guide...

Table of Contents