Relay Status Page - GE IDP-1111 User Manual

Legend series
Table of Contents

Advertisement

Relay Status page

To access the Relay Status page of Alarms, select Alarms and Relay Status.
Figure 44. Relay State page (
Alarms | Relay State
Note:
Remember to select OK to save any changes you make on the page.
Name. The Name column of the summary page lists both relays in numerical order, whether programmed
or not. The two relays are numbered 1 and 2.
State. The State column of the summary page lists the status of each programmed relay as either on
(active) or off (inactive).
Relay 1 on. The Relay 1 on button lets you turn relay 1 on regardless of the current state of any associated
alarm.
Note:
If you select Relay 1 on and select OK, then you are programming the dome to activate this relay each time
the dome is powered up.
Relay 1 off. The Relay 1 off button lets you turn relay 1 off regardless of the current state of any
associated alarm.
Relay 2 on. The Relay 2 on button lets you turn relay 2 on regardless of the current state of any associated
alarm.
Note:
If you select Relay 2 on and select OK, then you are programming the dome to activate this relay each time
the dome is powered up.
Relay 2 off. The Relay 2 off button lets you turn relay 2 off regardless of the current state of any
associated alarm.
Show relay state. The Show relay state feature, when checked, lets you display the status of the relays on
the monitor screen at all times. If the status of alarms is also being displayed, the relays will be listed at
the bottom of the list after the alarms.
)
Chapter 5
Advanced programming
67

Hide quick links:

Advertisement