Installation overview

The v2.1.9 software upgrade process has two steps. First, you will upgrade the software from v1.8.5
(or v1.8.5.1) to v1.8.6. Second, you will upgrade the software from v1.8.6 to v2.1.9. You cannot upgrade the
software directly from v1.8.5 to v2.1.9.

Required equipment (not provided)

The required equipment that is not provided, includes:
Computer (laptop or desktop)
Crossover cable (if connecting the computer directly to the dome)
Standard Ethernet cable (if connecting the computer through a hub device to the dome)

Two upgrade anomalies with v2.1.9

There are two minor upgrade anomalies that you may notice with the upgrade to v2.1.9.
One, this upgrade removes the 8 and 10 pt. options from the font size selections throughout the
software. Any type previously assigned 8 or 10 pt. will remain 8 and 10 pt., despite the selection for
that type now reading the first selection in the drop-down box. These settings will change only if you
change the setting and click OK on the page. If you click Discard (for discard change) after viewing
the page, the 8 or 10 pt. type will remain.
Two, this upgrade removes the 1, 2, and 3 second options from the relay duration selection on the
Contact Setup screen of the Alarms menu. Any relay durations previously assigned those times will
remain active as 1, 2, and 3 second durations, despite the selection for that duration now reading the
first selection in the drop-down box, which is 5 seconds. The settings will change only if you change
the setting and click OK on the page. If you click Discard (for discard change) after viewing the page,
the 1, 2, or 3 second duration will remain.