5.4 Advanced settings (for installers only)
Adjustments to „Advanced settings" and „Reset
settings" , as well as the following setups, should be
carried out by the installer only. Please do not modify
these settings unless you are a qualified system
installer, otherwise damages to the product and
possible injury might occur for which Solar Solutions
explicitly cannot be hold accountable for.
5.4.1 Setting of battery parameters
Installers can set the max. charging and discharging
current values according to the actual needs. The
checkboxes for „Use of battery V charged" and „Smart
lithium" should be ticked.
Specific Discharging settings:
Shutdown: the storage system will shut down if the
battery voltage drops below the given value.
Low Battery: the system will set off an alarm if the
battery voltage drops below the given value
Restart: the storage system will restart after
shutdown at the given value.
AEG LOW VOLTAGE ENERGY STORAGE UNIT (8 KWH / 12 KWH) INSTALLATION MANUAL
Specific Charging settings:
Generator charging:
Start voltage: the generator will start when the
battery voltage is less than the given „Start voltage"
value.
Current: The generator will charge the battery with
the given current value.
Grid charging:
Start voltage: the grid will start charging the
battery when the battery voltage is less than the
given „Start voltage" value.
Current: The grid will charge the battery with the
given current value.
5.4.2 Setting of grid parameters
To ensure a smooth operation of the AEG storage
system with the grid, select the correct grid settings,
which have to match with the local grid properties.
26
EN
PD202107 V1-21