3.3 Function scheme

3.3.1 Basic scheme

AC
DC
2
3
Item.
Description
1
AEG Energy storage system
2
Solar PV panels
3
Diesel generator
4
Meters
5
Grid
6
Monitoring (LCD)
7
House loads

3.3.2 Work modes

The AEG AS-BSL1-8000 / AS-BSL1-12000 energy
storage system works in the following modes:
Mode 1 - During daytime, the energy from the
photovoltaic plant is directed to charge the battery as
a priority. If / When the battery is fully charged, the PV
power will be used to power the loads, and the excess
power will be fed to the grid.
Mode 2 - During nighttime, the battery powers the
loads. If the energy in the battery is not sufficient, the
difference will be supplied by the grid.
Mode 3 - If the grid is subject to malfunction, or in
regions that are off-grid, the photovoltaic plant and the
battery can both concur to power the loads.
Mode 4 - When the battery is low and if power from the
photovoltaic plant is unavailable, the energy to charge
AEG LOW VOLTAGE ENERGY STORAGE UNIT (8 KWH / 12 KWH) INSTALLATION MANUAL
4
6
1
7
the battery and to power the loads will be supplied by
the grid.
Mode 5 - A generator can charge the battery
Mode 6 - If the function „Time Of Use" is on, it will
ensure that the power to charge the battery and the
power sold to the grid can be balanced.
5
Mode 7 - The UPS (Uninterrupted Power Supply)
Function can ensure that the main loads are still
powered even in case of sudden grid failure.

3.4 Technical data of the energy storage system

AS-BSL1-8000 and AS-BSL1-12000
PV Input
Max. recommended DC
power
Max DC voltage
Nominal DC operating
voltage
Start-up voltage
MPPT voltage range
V
range at full power
DC
Max.input current
Max.short current
Number of MPPT trackers
Strings per MPPT tracker
AC Input & AC Output
Normal Voltage
Frequency
Max. AC output current
Max. AC input current
Max. continuous power
Power factor range
Off-Grid AC Output
Normal Voltage
Frequency
Max. AC output current
Max. continuous power
11
bank..
[W]
6500
[V]
500
[V]
360
[V]
150
[V]
125-425
[V
] 250-425
DC
[A]
11/11
[A]
16/16
2
1/1
[V
] 230,
AC
Single phase
(L/N/PE)
[Hz]
50 / 60
[A]
25
[A]
25
[kW]
5
-0.8 ~ +0.8
[VAC] 230,
Single phase
(L/N/PE)
[Hz]
50 / 60
[A]
25
[kW]
5
EN
PD202107 V1-21