Technical Data Of Battery Module; Operating Data; Bms (Battery Management System) - AEG AS-BSL1-8000 Series Manual

Low voltage energy storage unit
Table of Contents

Advertisement

Peak power
Power factor range
Storage Data
Battery type
Number of battery modules
Nominal storage capacity
Usable storage capacity
Battery capacity
Normal voltage
Voltage range
Max. charge current
Max. discharge current
DOD
Cycle life
Regular parameters
Protective class
Overvoltage category
Display
Communication
Operating temperature
range
Storage stability range
Relative humidity
Altitude
Cooling methods
Ingress protection
Condition
Certificates:
IEC/EN 62109-2:2011; IEC/EN 62109-1:2010;
Low Voltage Directive 2014/35/EU;
EN 61000-6-1: 2007; EN 61000-6-3: 2007/+A1: 2011;
EMC Directive 2014/30/EU;
CE-LVD EN 62477-1: 2012+ALL: 2014;
RoHS Directive 2011/65/EU and (EU)2015/863;
EU REACH Regulation No 1907/2006 Article 33(1)
Warranties
For the latest warranties please refer to:
www.aeg-industrialsolar.de
AEG LOW VOLTAGE ENERGY STORAGE UNIT (8 KWH / 12 KWH) INSTALLATION MANUAL
1.5 times of
Max. continuous
power (10S)
-0.8~+0.8
AS-
AS-
BSL1-
BSL1-
8000
12000
Lithium (LFP)
2
3
[kWh] 7.68
11.52
[kWh] 6. 1 4
9.22
[Ah]
150
225
[V]
51.2
[V]
42-58
[A]
100
[A]
100
80%
6000
Class I
OVC II (PV),
OVCIII (AC main
grid)
[°C]
7'' graphic LCD
WIFI, CAN
[°C]
-10~+40
(>45° derating)
[°C]
-20~+60
0~95%
[m]
<2000
Forced airflow
IP20
Indoor
conditioned

3.5 Technical data of battery module

Electrical characteristics
Battery type
Total energy capacity
Usable energy capacity
Battery capacity
Voltage range / usable..v.r.
Nominal voltage
Charge current
(recommended)
Disharge current
(recommended)
Max. continuous charge
current
Max. continuous discharge
current
DOD
Internal resistance
Cycle life at 25°C
(under standard charge
conditions, charge 0.2°C,
discharge 0.2°C
DC disconnect
Warranties
For the latest warranties please refer to:
www.aeg-industrialsolar.de

3.6 Operating data

BMS (Battery Management System)

Power consumption (work) [W]
Power consumption (sleep) [mW] <100
Communication
Monitoring parameters
Protection
12
LFP
[kWh] 3.84
[kWh] 3.07
[Ah]
75
[V]
48~57.6
[V]
51.2
[A]
37.5 A
[A]
37.5 A
[A]
50
[A]
50
80%
[m ] ≤60
≥6000
Contactor
<3
CAN
System voltage, system
current, cell voltage, cell
temperature
Overvoltage,
undervoltage,
overcurrent,
overtemperature,
undertemperature
EN
PD202107 V1-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-bsl1-12000 seriesAs-bbl1-4000

Table of Contents