AEG AS-BSL1-4000 Series Installation Manual
AEG AS-BSL1-4000 Series Installation Manual

AEG AS-BSL1-4000 Series Installation Manual

Low voltage energy storage unit battery pack

Advertisement

Quick Links

AEG ENERGY STORAGE
INSTALLATION
MANUAL
AEG LOW VOLTAGE ENERGY STORAGE UNIT
SERIES: AS-BSL1-4000
AEG BATTERY PACK AS-BBL1-4000
AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 KWH) INSTALLATION MANUAL
VERSION:
PD202107 V1-21

Advertisement

Table of Contents
loading

Summary of Contents for AEG AS-BSL1-4000 Series

  • Page 1 AEG ENERGY STORAGE INSTALLATION MANUAL AEG LOW VOLTAGE ENERGY STORAGE UNIT SERIES: AS-BSL1-4000 AEG BATTERY PACK AS-BBL1-4000 AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 KWH) INSTALLATION MANUAL VERSION: PD202107 V1-21...
  • Page 2: Table Of Contents

    Settings menu Selecting the power source; setting the charging / feed- in intervals and speed Choosing how to use stored energy Setting language and time Checking product information AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 3: Preliminary Remarks

    10min touching internal parts Note Useful information for product maintenance and operation is Product surface may become hot, do not provided touch Table 1: Icon meaning AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 4: Safety

    AEG energy storage unit (AS-BSL1-4000) and the AEG battery pack (AS-BBL1-4000). Heavy, handle with care to avoid injury Look for any visible damage to the package or the AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 5 Keep the energy maintenance of the energy storage system. storage system and the battery pack away from the reach of children. AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 6: Grid-Tied Operation Safety

    The electronic components of the energy storage and components inside the inverter are electrostatic. system may be damaged by static electricity. Please take appropriate protective measures to prevent such AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 7 If you find yourself in any of the below emergency situations resulting from exposure to electrolyte, please take the suggested take promptly: AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 8: Product Overview

    AEG energy storage system, the battery pack can also function as uninterruptible power supply (UPS) and work within a micro-grid. Item. Description System door lock Door key LCD screen AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 9: Battery Module

    The wiring port can be seen in detail after opening the cover plate. Item Description Size Width 678 mm Depth 205 mm Height 436 mm Weight 60 kg AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 10: Can Communication Interface (Can1 & Can2)

    2) Warning indicator: If there is no alarm, the light will always be on. If there is any warning, the light will blink. CANH CANL AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 11: Function Scheme

    Mode 4 - When the battery is low and if power from the Peak power 1.5 times of Max. photovoltaic plant is unavailable, the energy to charge continuous power (10S) AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 12: Technical Data Of Battery Module

    EU REACH Regulation No 1907/2006 Article 33(1) Monitoring parameters System voltage, system Warranties current, cell voltage, cell For the latest warranties please refer to: temperature www.aeg-industrialsolar.de Protection Overvoltage, undervoltage, overcurrent, overtemperature, undertemperature AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 13: Operating Conditions

    The below installation material should be arranged by the installer for the installation of the battery pack: Phillips-screwdriver (M6,M8) • Charging cables • Network cable Straight screwdriver Hexagon wrench AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 14: Wire Specifications

    The cabinet hosting the energy storage system is IP20 and suitable for installation in dry, dust-free environments. According to EMC standards, the system is designed to meet the installation requirements in a home environment. AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 15: Mechanical And Electrical Installation

    (see 2.2 „Handling safety“.). Item. Description System cabinet Battery module case Item. Description System cabinet Battery module AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 16 Item. Description Combination screw Fixing bracket Item. Description Communication cable 2, 3 CAN1 port; PIN4: CANH / PIN5: CANL CAN2 port; PIN4: CANH / PIN5: CANL AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 17: Pv Connection

    The maximum open circuit voltage of each PV crimping torque is 1.5–2.5 N•m. string should never be higher than the maximum • Connect the three wires L, N, and PE of the load to AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 18: Warnings

    (three- and single-phase) operation on the E-bar AC-backup. Parallel operation of the AEG storage E-bar system will void the warranty. Generator Normal loads 3-phase load Notes: +22° • CT direction: towards grid AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 19: Operation

    5. OPERATION 5.1 Operating the AEG battery pack There are two ways to operate the AEG battery pack AS-BBL1-4000: 1-phase load Method 1: Short PIN2 and PIN3 of Remote port first, then press the metal button switch. The battery pack will start to work within 25 seconds.
  • Page 20: Switching On/Off The Aeg Energy Storage System

    In the following section you will find detailed information on each section and sub-menu, and how to set the parameters of the AEG energy storage system. Item. Description Touchscreen LCD panel AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 21: The Main Menu

    Data, Production Information, and Battery Capacity. 5.3.3 Checking system information in the Status menu The „Status“ menu displays informations such as: PV information, Load information, Grid information, and Battery information AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 22: Checking And Adjusting System Settings In The Settings Menu

    If you do not wish that the battery feeds back energy AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 23: Setting Language And Time

    The „Advanced choose the system languages from a set of given settings“ and „Reset languages (default: English). settings“ sub-menus within the „Settings“ menu shall be operated by installers. AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 24 PV plant, grid feed-in, and environmental statistics. 5.3.6 Checking Fault messages If there is any fault during the AEG energy storage system operation, a blinking „Fault“ icon will appear in the right upper corner of the LCD screen. Clicking on the „Fault“...
  • Page 25 Low Battery: the system will set off an alarm if the battery voltage drops below the given value • Restart: the storage system will restart after shutdown at the given value. AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 26 6.2 Energy storage system warnings and troubleshooting 6.2.1 Fault codes In case the AEG energy storage system incurs into an issue, this will be signaled by a warning on the LCD screen. Please find below the fault codes and the description of the associated issue.
  • Page 27 AC main contACtor failure Reactor B phase current high Reactor C phase current high AC secondary contactor failure IGBT Heat sink high temperature Inverter 2 DC high fault AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 28 2 - Restart the inverter correctly connected 3 - If the problem persists, 3 - If the problem persists, please contact your please contact your installer / distributor installer / distributor AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 29 Solar Solutions’s control. Solar Solutions expressly disclaims liability for loss, damage, or expenses arising out of or in any way connected with such installation, operation, use or maintenance. AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL PD202107 V1-21...
  • Page 30 60594 Frankfurt am Main, Germany __________________________________________________________ www.aeg-industrialsolar.de __________________________________________________________ Mail: service@aeg-industrialsolar.de __________________________________________________________ Tel: +49 (0)69400500810 __________________________________________________________ AEG is a registered trademark used under license from AB Electrolux (publ). __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ AEG LOW VOLTAGE ENERGY STORAGE UNIT (4 kWH) INSTALLATION MANUAL...

This manual is also suitable for:

As-bbl1-4000