Generic Binding; Configuration Modes - Honeywell evohome Applications Manual

Hide thumbs Also See for evohome:
Table of Contents

Advertisement

4.

Generic Binding

New components of the zoning system, which have capabilities to communicate wireless based on 868 MHz technology,
have to be integrated into the system before they can be taken into operation. This process is called BINDING
The binding procedure in the evotouch controller is guided by help screens which lead the installer through the
procedure.
Only the peripheral devices like actuators, sensors etc. have to be set into the individual bind mode by pressing e.g. the
BIND button.
After BINDING, the peripherals are able to communicate with the evotouch controller to receive or transmit data. In
addition, the RF communication can be checked and the signal strength is indicated and displayed.
As an example the following procedures are described for a living room.
4.1

Configuration modes

The zone configuration of the evotouch controller basicly can be done by the GUIDED Configuration and EXPERT
Configuration.
Particularly if you have mixed applications e.g. 4 zones radiator control and 2 zones underfloor heating control the
configuration mode which should be applied is described in the specific application Multizone system with radiators
and underfloor heating and Multizone system with mixing valve and radiators.
4.1.1
GUIDED configuration
f
Press and hold the MENU button until the next screen
appears.
f
Press the YES button.