2.7
Multizone system with radiators and underfloor heating
Example: 6 zones, up to 8 zones are possible
Z o n e 4
Z o n e 2
) /
8 0 ( R
H C E
)
8 0 ( R
H C C
9 1
B D R
B o i l e
r r o o m
Notes
•
The internal room sensor of the
•
Instead of DT92 the HCW82 / HCF82 room units can be used
•
Zone 3: HR80 internal room sensor not used
•
Optional boiler feedback: BDR91 relay module or OPENTHERM-Bridge
For that mixed application you can setup the configuration as following:
f
Select menu GUIDED CONFIG and configure the 4 zones for radiator control
Select menu ZONING CONFIG and add the 2 zones for underfloor heating control ADD ZONE
f
Alternative go to the expert menu:
f
Select menu ZONING CONFIG and add the 4 zones for Radiator control ADD ZONE
f
Select menu ZONING CONFIG and add the 2 zones for underfloor heating control ADD ZONE
The Binding process in the EXPERT MENÜ is the same as for GUIDED CONFIGURATION however the RF test must be
choosen in the MENU SYSTM CONFIGURATION BINDING AND RF TEST individual for each zone.
18
Z o n e 5
Z o n e 6 .. . 8
Z o n e 3
c h
t o u
e v o
Z o n e
1
evotouch controller must be activated for zone 1
evotouch