Sony MVS-8000 User Manual page 85

Multi format switcher system
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

5
To disable a button
In the Panel >Xpt Assign >Main, V/K Pair Assign menu, select the button you
want to disable, and press [Inhibit].
To delete any currently assigned signal
In the Panel >Xpt Assign >Main, V/K Pair Assign menu, select the button
corresponding to the signal you want to delete, and press [Delete] in the <Xpt
Assign> group.
Signal deletion is executed in accordance with the selection in the <Assign>
group, and the signal assigned to the button number next to the selected button
number and following signals move up one line.
Notes
When a button number in the range 121 to 128 is selected, execution of
"Delete" is impossible. The signal assignments to button numbers 121 to 128
cannot be changed. When a signal assigned to any other button number is
deleted, moving up of signals ends when the signal assigned to number 120 has
moved to number 119, and the signals assigned to numbers 121 to 128 are
maintained in their original lines.
Creating tables 1 to 14
When creating tables 1 to 14, in the same way as when creating the main table,
you can assign the same signal to more than one button number, or delete
84
Cross-Point Settings (Xpt Assign Menu)
• Turn the knob.
Knob
Parameter
Adjustment
3
Source No
Selection of source to be assigned
Using the buttons in the <Xpt Assign> group, assign the selected signal to
the button number currently selected in the main table.
Set: Delete the signal currently assigned to the selected button number and
make a new assignment.
Insert: Move down one line the signal currently assigned to the selected
button number and following signals, and make a new assignment.
Notes
When a button number in the range 121 to 128 is selected, execution of
"Insert" is impossible. The signal assignments to button numbers 121 to
128 cannot be changed. When "Insert" is executed for any other number,
moving down of signals ends at number 120, and the signals assigned to
numbers 121 to 128 are maintained in their original lines.
Setting values
1 to 128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-8000sf

Table of Contents