The selected setting appears in the status area.
Selectable actions for various trigger types
• When the trigger type is other than "Level"
When Target is M/E-1, M/E-2, or M/E-3: Cut, Auto Trans
Key1 Cut, Key2 Cut, Key3 Cut, Key4 Cut
Key1 Auto Trans, Key2 Auto Trans, Key3 Auto Trans, Key4 Auto
Trans
Key1 SS ? Recall, Key2 SS ? Recall, Key3 SS ? Recall, Key4 SS ?
Recall
When Target is P/P: Cut, Auto Trans
DSK1 Cut, DSK2 Cut, DSK3 Cut, DSK4 Cut
DSK1 Auto Trans, DSK2 Auto Trans, DSK3 Auto Trans, DSK4 Auto
Trans
DSK1 SS ? Recall, DSK2 SS ? Recall, DSK3 SS ? Recall, DSK4 SS ?
Recall
FTB Cut, FTB Auto Trans
When Target is Common/Setup:
Master SS ? Recall, Master Effect ? Recall, SS ? Recall, Effect ?
Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, FM
Src1 Frame Freeze, FM Src1 Field Freeze, FM Src1 Freeze Off, FM
Src2 Frame Freeze, FM Src2 Field Freeze, FM Src2 Freeze Off, FM
Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip Record, FM Src2
Clip Stop, FM1 to FM8 Clip Cueup, FM1 to FM8 Clip Play, FM1 to
FM8 Clip Stop, Shotbox ? Recall, Macro Take, Prefs Button?, Macro
? Recall, No Action
(FM Src1(2) Clip Record/Stop, and FM1 to FM8 Clip Cueup/Play/Stop do not
operate on the MVS-8000.)
• When the trigger type is only "Rising Edge" or "Falling Edge"
Aux? O'ride Src??
• When the trigger type is "Level"
When Target is M/E-1, M/E-2, M/E-3, or P/P: No Action
When Target is Common/Setup: Format
Aspect (overall system settings), Simul, Level Enable, No Action
Notes
• "Level Enable" is a function that determines whether GPI inputs are enabled
("Enable") or disabled ("Disable") for the "Aspect" and "Format" actions
that can be used when the trigger type is Level. When Level Enable is used,
if the input is "Disable" then it is not possible to switch "Aspect" or "Format"
by GPI input.
If a GPI to switch "Aspect" or "Format" occurs when powering the system
off, the action triggered by the GPI may start immediately before the power
goes off and the power may go off before the action is completed. This may
corrupt the setup settings. It is therefore recommended to use Level Enable
to avoid such a situation.