Honeywell CNI4 Operating And Installation Manual page 55

Table of Contents

Advertisement

9 Appendix
ITEM Number
3138
3139
3140
3141
3142
3143
3144
3425
3426
3427
Parameter
Modem server timeout
Remote Unit ID 2 (RUID)
Temperature units
BLE number of bonds
MIWireless Enable
BLE start time
BLE stop time
Factory test access number
Factory test mode status
Factory test item number
Parameter Description
7 = ITEM_RESTORE_DEFAULTS_SECURITYCONFIG
8 = ITEM_RESTORE_DEFAULTS_BATTERYCONFIG
9 = ITEM_INITIATE_RESET
10 = ITEM_INITIATE_BLE_RESET
11 = ITEM_RESTORE_DEFAULTS_
INTERNALCONFIG
This timeout is used in EC 350 mode whenever
modem IP/Port numbers are for found.
Default Value : 000000
Must be same as that of the connected instrument.
0 = °C
1 = °F (default)
The number of bluetooth bonds. A bond information
is used to establish a secure link or to verify a
device's identity, so when the devices reconnect
they do not have to go through the initial stages
like performing service discovery, configuring the
descriptors again.
0 = for EC 350 (default)
1 = MiWiress
(When this item number is changed, the instrument
must be restarted)
Time when bluetooth communication started
Time when bluetooth communication stopped
Access code to enter into factory mode
Status to check whether CNI4 board is in Factory
mode or not
FT_MODEM_POWER_ON= 1,
FT_MODEM_POWER_OFF= 2,
FT_SIM_TEST= 3,
FT_SRAM_TEST= 4,
FT_DATA_FLASH= 5,
FT_OTA_FLASH= 6,
Honeywell
| 52