9 Appendix
Ch Item #
Default = 01-01-99,
Format: MM-DD-YY
Gas Day Start Time
205
Default = 09 00 00
Date Format
Select :
262
0 - MM-DD-YY Default
1 - DD-MM-YY
2 – YY-MM-DD
Audit Trial Configuration Items
450
Memory Capacity
481
Audit Trail Max Records
Audit Trail Data Item 1
of 10
258
Default: 002
(Ch1Accumulated
Volume)
Audit Trail Data Item 2
259
of 10
Item Name
onboard real-time clock. The format of the Date is determined
by the selection at item 262 and may be displayed as MM-
DD-YY, DD-MM-YY, or YY-MM-DD. The Date automatically
tracks the days in the month, including leap year. When
configuring this item, leading zeros are required where
applicable. This Date and Time (from Item
203) are used to time-stamp the records in Audit Trail
memory.
User selectable time to indicate the beginning of the GAS
DAY, which by definition for other items, is the time of day
when daily computations are re-zeroed to begin the next
day's computations. Note: The time entered should only
contain zeros for minutes and seconds.
Codes (0-2) to select the format in which the Date is entered
and displayed at item
204. The format for all date-related items will also be
governed by this item
Aread-only value indicating audit trail memory capacity,
expressed in days or months, based on the maximum number
of audit trail records at item 481.
A read-only value indicating the maximum number of audit
trail records available for this particular product
The first of ten user selectable Audit Trail Report Items that
can be configured for Audit Trail logging. To use these ten
items, insert the desired item code
number into any of the report locations (258 - 261 and 229 -
234). The value "255" at any of these Report Items will cause
that position to be 'blank'.
Description