Item
No.
Item Name
————————————————————————————————————————
062
SERIAL NUMBER
063
PCOR MIN PRESS
064
GAS TEMP MAX
065
GAS TEMP MIN
066
PULSER A LIMIT
067
PULSER B LIMIT
068
PULSER C LIMIT
069
PULSER A ALARM
070
PULSER B ALARM
www.honeywell.com
96
Mini-AT User Guide
Description
Factory assigned Instrument Serial Number. Example: 09901234
09901234 - disregard the leading zero.
09901234 - 2 digit year of manufacture.
09901234 - 5 digit sequence # during the year of manufacture.
Default = 00000000
Lowest PCor pressure measured at item 008 since last manual
reset.
Default = 099999.99
Highest temperature measured at item 026 since last manual
reset.
Default = -40.00
Lowest temperature measured at item 026 since last manual
reset.
Default = 099999.99
High limit for the number of pulses accumulated in item 005.
Initiates an alarm (item 069) when exceeded.
Default = 99999999
High limit for the number of pulses accumulated in item 006.
Initiates an alarm (item 070) when exceeded.
Default = 99999999
High limit for the number of pulses accumulated in item 007.
Initiates an alarm (item 071) when exceeded.
Default = 99999999
If the value at item 005 (Pulser A) exceeds the Pulser A Limit (item
066), an alarm is initiated. The LCD will display 'dots' while in
the Corrector Mode, and item 069 will display "11111111" if view
by the Meter Reader Mode or software. "00000000" is displayed
if item 069 has no alarm.
Default = 00000000
If the value at item 006 (Pulser B) exceeds the Pulser B Limit (item
067), an alarm is initiated. The LCD will display 'dots' while in
the Corrector Mode, and item 070 will display "11111111" if view
by the Meter Reader Mode or software. "00000000" is displayed
if item 070 has no alarm.
Default = 00000000