Mo Pk Hr Corvol; Mo Pk Hr Date; Mo Pk Hr Time; Mo Pk Day Corvol - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Item
No.
Item Name
————————————————————————————————————————
243

MO PK HR CORVOL

244

MO PK HR DATE

245

MO PK HR TIME

246

MO PK DAY CORVOL

www.honeywell.com
124
Page 124
Mini-AT User Guide
Description
For items 235 thru 239 and 242, code (0 - 1) to activate or
deactivate the above listed audit trail Report Triggers. If activated,
an audit trail record will appear in the audit trail log at the
occurrence of each particular type of trigger. The entry appears as
a time-stamp record, consisting of the following fields in a left-to-
right order. If the unit is configured for just four audit trail items,
Optional Report Items 1-6 are omitted from the audit trail record.
Column:
Field
1
DATE (204),
2
TIME (203),
3
SELECTABLE REPORT ITEM #1 (258),
4
SELECTABLE REPORT ITEM #2 (259),
5
SELECTABLE REPORT ITEM #3 (260),
6
SELECTABLE REPORT ITEM #4 (261),
7
OPTIONAL REPORT ITEM #1 (229),
8
OPTIONAL REPORT ITEM #2 (230),
9
OPTIONAL REPORT ITEM #3 (231),
10
OPTIONAL REPORT ITEM #4 (232),
11
OPTIONAL REPORT ITEM #5 (233),
12
OPTIONAL REPORT ITEM #6 (234),
13
REPORT TRIGGER (items 235-239, 242
or 173-175)
If any Report Trigger(s) is deactivated, that particular type of an
event (trigger) will not appear as a time-stamped record in audit
trail memory.
Select: 0 - Inactive
1 - Activated-----Default
The highest hourly CORVOL of the current 'Gas' month.
Default = 00000000
The date the current month Peak Hour CORVOL (243) occurred.
Format: Determined by item 262
Default = 01-01-98
Ending hour for the current month Peak Hour CORVOL Date
(244).
Default = 00 00 00
The highest Daily CORVOL (item 223) of the current 'Gas' month.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents