Description
Factor to provide for other possible corrections to metered
volume, i.e. Water Vapor Content, Therms, etc. If not
applicable, set to 1.0000.
Default = 1.0000
AGA 3 / NX-19 or AGA 8 Supercompressibility factor
calculated at the most recent wake-up from values at items
008, 026, 053, 054 and 055, if item 110 is set for LIVE. May
be fixed factored to any reasonable value entered, by the user,
if item 110 is set for FIXED.
Default = 1.0000
Main battery voltage measured at last wake-up.
Default = 0.00
Low limit for main battery voltage, initiates alarm (item 099) if
voltage drops below this value.
Default = 5.50
The voltage level at which most of the electronic circuits
terminate operation. "..H.E.L.P.." is displayed on the LCD as
an indication that the battery is dead and needs replaced. The
upper limit setting for this item is 5.50 volts.
Default = 4.80
Voltage level of the Backup Battery measured at the most
recent wake-up.
Default = 0.00
Low voltage limit for Backup Battery, initiates alarm (item
101) if voltage drops below this value.
Default = 3.60
Specific gravity, entered by the user, for calculating NX-19
Supercompressibility factor at item 047.
Default = 0.6000
Percentage of Nitrogen molecules, entered by the user, for
calculating NX-19 supercompressibility factor at item 047.
Default = 0.0000
Percentage of Carbon Dioxide molecules, entered by the user,
for calculating NX-19 supercompressibility factor at item 047.
Default = 0.0000