Sltble Rep Item 1; Date Format; At Timelog Timestamp; Jumper Settings - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Item
No.
Item Name
————————————————————————————————————————
258

SLTBLE REP ITEM 1

259
SLTBLE REP ITEM 2
260
SLTBLE REP ITEM 3
261
SLTBLE REP ITEM 4
262

DATE FORMAT

263
AT TIMELOG TIMESTAMP Selection to determine how Audit Trail data is downloaded from
268

JUMPER SETTINGS

www.honeywell.com
126
Mini-AT User Guide
Default = 0.00
Description
The first of four user selectable Audit Trail Report Items that can be
configured for Audit Trail memory. To use these four items, insert the
desired item code number into any of the report locations (258 - 261).
The value "255" at any of theseReport Items will cause that position
to be 'blank'. The Audit Trail logger can be configured to record four
or ten item values in each audit trail record. See Item Codes 229 - 234
for further information.
See above.
See above.
See above.
Code (0 - 2) to select the format in which the Date is entered and
displayed at item 204. The format for all date related items (213,
244, 247, etc.) will also be governed by the selection of item 262.
Select: 0 - MM:DD:YY-----Default
the instrument. Selecting '0' will download audit trail records the
same as in the past. (i.e. when a snapshot of the Audit Trail item
values were taken.) Selecting '1' will shift interval based values
(ex. Item 225 Incremental Corrected Volume) into the previous
time log (i.e. start of the interval). Absolute values (ex. Item
000 Corrected Volume) will remain in their original time log (i.e.
end of the interval). This feature was added to allow incremental
Audit Trail data (consumption) to be displayed at the time interval
of its usage.
Select: 0 - End of Interval Default
The Mini-AT incorporates jumpers on the main circuit board as
another means of configuring some modes of operation. Since the
jumpers are physical entities, they cannot be changed via software.
Item 268 provides a means of reporting which jumpers are installed
at JB24. Normally (i.e. default), the only jumper installed at JB24
is across pins 5 & 6. Other jumper may be installed if those
Default:
225
(Incrv CorVol)
Default:
226
(Incrv UnVol)
Default:
206
(Avg. PCor Gas Pressure)
Default:
207
(Avg. Temperature)
1 - DD:MM:YY
2 - YY:MM:DD
1 - Start of Interval