Appendix 4-6-4 Surge protector

Insert a surge protector in the power input section to prevent damage to the control panel caused by the
surge (lightning or sparks, etc.) applied on the AC power line.
Use a surge protector that satisfies the following electrical specifications.
(1) Surge protector for 200V
200V R・A・V BYZ Series
Circuit
Part name
voltage
50/60Hz
RAV-781BYZ-2
3AC 250V
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications.
200V R・A・V BXZ Series
Circuit
Part name
voltage
50/60Hz
RAV-781BXZ-4
3AC 250V
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications.
Outline dimension drawings
41±1
41±1
Appendix 4. EMC Installation Guidelines
Maximum
Clamp
tolerable
voltage
circuit voltage
300V
783V
Outline dimension drawings
41±1
41±1
Maximum
Clamp
tolerable
voltage
circuit voltage
300V
1700V
Surge
Surge
withstand
withstand
level
voltage
8/20 µS
1.2/50 µS
±
10%
2500A
20kV
Circuit diagram
(1) Black
(2) Black (3) Black
UL-1015 AWG16
Surge
Surge
withstand
withstand
level
voltage
8/20 µS
1.2/50 µS
±
10%
2500A
Circuit diagram
(1) Black (2) Black
UL-1015 AWG16
A4 - 15
Electrostatic
Service
capacity
temperature
75pF
-20 to 70°C
[Unit: mm]
Electrostatic
Service
capacity
temperature
2kV
75pF
-20 to 70°C
(3) Black
Green
U
[Unit: mm]