Overview of Alarms
8098
Invalid combination of options (%1)
Parameters:
%1 = Bit mask of options
Definitions:
The following restrictions apply to this module for the combination of options:
The option "Two-channel" and the options "External language", "Nibbling", "Neural quad-
rant error compensation" and "Measurement level 2" exclude one another!
Bit0 (LSB): Nibbling
Bit1
Bit2
Bit3
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Set the options accordingly.
Program Con-
Switch control OFF - ON.
tinuation:
8100
Channel %1 block %2: function not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
• Impossible due to embargo regulations:
• 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC,
$AA_OVR, $AA_VC and $AA_OFF) from synchronous actions as well as Continuous
Dressing can be programmed only once in a block.
• 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from syn-
chronous action' is not possible.
• 3. Axis interpolation: The number of axes interpolating with one another must not
exceed 4 (this also includes synchronous coupling of axes via synchronous actions "DO
POS[X]=$A..." "DO FA[X]=$A...").
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10200
[up to SW 3.x] Channel %1 NC start with active alarm not allowed
Parameters:
%1 = Channel number
Definitions:
An alarm is currently active, the internal reaction to which is to inhibit an NC start.
Reactions:
- Alarm display.
Remedy:
Find and eliminate the cause of the alarm.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
10202
[up to SW 3.x] Channel %1 NC start not possible
2-88
: External language
: Neural quadrant error compensation
: Measurement level 2
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005