Overview of Alarms
Please inform the authorized personnel/service department. No remedial measures are
possible - the operation triggering the alarm message has to be repeated. Clear the alarm
display with Cancel.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6000
Memory reorganized using standard machine data
Definitions:
The memory management was not able to allocate the NC user memory with the values
in the machine data. Because the total memory available is provided as dynamic and
static memory for the NC user (e.g. for macro definitions, user variables, number of tool
offsets, number of directories and files etc.) and therefore its size is not adequate.
Reactions:
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Redefine the NC memory
structure!
A specific machine data for NC user memory allocation cannot be given as the cause of
the alarm. Therefore, the MD initiating the alarm must be determined on the basis of the
default values in the machine data by changing the user-specific memory structure step
by step.
Usually, not just one machine data has been chosen too large and therefore it is advis-
able to reduce the memory area by a certain proportion in several MDs.
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
6010
Channel %1 data block %2 not or not completely created, error code %3
Parameters:
%1 = Channel number
%2 = String (block name)
%3 = Internal error code
Definitions:
Data management has detected an error in power-up. The specified data block may not
have been created. The error number specifies the type of error. If the error number
>100000, then there is a fatal system error. Otherwise, the user memory area was made
too small. In this case the (user) error codes have the following meaning:
• Error number 1: No memory space available
• Error number 2: Maximum possible number of symbols exceeded
• Error number 3: Index 1 outside of valid value range
• Error number 4: Name in channel already exists
• Error number 5: Name in NCK already exists
If the alarm occurs after cycle programs, macro definitions or definitions for global user
data (GUD) have been introduced, the machine data for the NC user memory configura-
tion have been incorrectly configured. In all other cases, changes to machine data that
are already correct lead to errors in the user memory configuration.
The following block names (2nd parameter) are known in the NCK (all system and user
data blocks; in general, only problems in the user data blocks can be remedied by user
intervention:
• _N_NC_OPT - System internal: option data, NCK global
• _N_NC_SEA - System internal: setting data, NCK global
• _N_NC_TEA - System internal: machine data, NCK global
• _N_NC_CEC - System internal: 'cross error compensation'
2-60
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005