Siemens SINUMERIK 840D sl Series Diagnostics Manual page 345

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Increase the number of the R
parameters or reduce the FIFO elements.
$MC_MM_NUM_R_PARAM = $MC_START_AC_FIFO + $MC_NUM_AC_FIFO x
($MC_LEN_AC_FIFO + 6)
Program Con-
Switch control OFF - ON.
tinuation:
20200
Channel %1 invalid spindle number %2 with tool fine compensation
Parameters:
%1 = Channel number target channel
%2 = Spindle number
Definitions:
There is no spindle/axis assignment in the target channel for the spindle specified in the
PUTFTOC command.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Modify program in channel that writes the tool fine compensation.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
20201
Channel %1 spindle %2 no tool assigned
Parameters:
%1 = Channel number
%2 = Spindle number
Definitions:
In order to make allowance for the fine tool compensation for the tool currently in the spin-
dle, a spindle/tool assignment must be active. This is not presently the case for the pro-
grammed spindle in the target channel of fine tool compensation.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
1. Modify the part program (write the tool fine compensation).
2. Establish spindle/tool assignment by programming:
• TMON (tool monitoring)
• GWPSON (tool selection)
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
20203
Channel %1 no active tool
Parameters:
%1 = Channel number
Definitions:
A tool fine compensation has been written for the active tool of channel %1 with PUTF-
TOC. No tool is active in this channel. Therefore, the compensation cannot be assigned.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-345