08/2005
- Alarm display.
Remedy:
Define the safety clearance.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61123
Channel %1 Block %2: CYCLE72 cannot be simulated
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE72.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61124
Channel %1 Block %2: Infeed width is not programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE71.
Reactions:
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Remedy:
With active simulation without tool, a value for the infeed width _MIDA must always be
programmed.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61125
Channel %1 block %2: Technology selection in parameter _TECHNO incorrectly
defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reactions:
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Remedy:
Check parameter _TECHNO.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61126
Channel %1 block %2: Thread length too short
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE840.
Reactions:
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-447