Fire Alarm Control Panel IQ8Control C / M
Trouble
Possible Cause
Code No.
Detector circuitry has been
changed at detector location.
089
Now detector has external circuit.
(relay / LED).
Detector circuitry has been
changed at detector location.
090
Now detector has an isolating
relay.
The IQ8Quad detector circuit has
been changed at the detector
091
location. Voice output is now also
possible.
The IQ8Quad detector circuit has
been changed at the detector
092
location. An optical alarm is now
also possible.
The IQ8Quad detector circuit has
been changed at the detector
093
location.
Voice output is no longer
possible.
The IQ8Quad detector circuit has
been changed at the detector
094
location. An optical alarm is no
longer possible.
2
A O
T-detector has been
installed at detector location. The
095
detector type has changed in
comparison with the customer
data.
The IQ8Quad detector circuit has
been changed at the detector
096
location. An optical and/or
acoustic alarm is no longer
possible.
The IQ8Quad detector circuit has
been changed at the detector
097
location. An optical and/or
acoustic alarm is now also
possible.
Ionisation smoke detector or fire detector with ionisation sensor may only be installed/maintained
by authorised persons with handling license issued under the Radiation Protection Ordinance
(German: Strahlenschutzverordnung - StrlSchV).
120
1st. measure
Check whether this detector
location is to have an external
circuit. isolating relay. If it is,
activate loop.
Check whether this detector
location has an isolating relay.
If it has, activate loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
Check whether detector type
change is desired; if it is,
activate loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
Check if the detector type
change is desired; if yes,
reprogram the customer data
and switch on the loop.
2nd. measure
Otherwise install detector
you require and re-start
>Detector change<
Otherwise install detector
you require and re-start
>Detector change<
Otherwise, install desired
detector and restart
>Detector replacement<
Otherwise, install desired
detector and restart
>Detector change<
Otherwise, install desired
detector and restart
>Detector change<
Otherwise, install desired
detector and restart
>Detector change<
Otherwise install detector
you require and re-start
>Detector change<
Otherwise, install desired
detector and restart
>Detector change<
Otherwise, install desired
detector and restart
>Detector change<
FB 798951.10.GB0 / 04.15