12. Exciter field coil AC voltage
9 Disconnect the exciter field coil coupler.
9 Connect the pocket tester (AC 20 V) as
shown.
9 Start and run the engine.
B
W
9 Measure the exciter field coil voltage.
Exciter field coil AC voltage
(Black–White):
17 V
MEETS
SPECIFICATION
GENERATOR SYSTEM
OUT OF SPECIFICATION
13. Exciter field coil resistance
9 Disconnect the exciter field coil coupler.
9 Connect the pocket tester (W × 1) as
shown.
9 Measure the exciter field coil resistance.
Exciter field coil resistance
(Black–White):
46.5 W ± 10 %
OUT OF
SPECIFICATION
Replace the exciter field coil.