Transmitter; Receiver (A-Frame); Pre-Operation Inspection; Set-Up And Operation Instructions - RIDGID A-Frame Operator's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Transmitter:

1. With device OFF, remove the battery com-
partment cover. If needed, remove batter-
ies (Figure 6).
+
-
+
Batteries
Figure 6 – Changing the Batteries (Transmitter)
2. Install eight new C Cell alkaline batteries
(R14), observing correct polarity as indi-
cated in the battery compartment.
3. Securely reinstall the battery compart-
ment cover.

Receiver (A-Frame):

1. With device OFF, unscrew the battery
com partment cover on the top tube (Fi-
gure 7). If needed, remove batteries.
Batteries
Figure 7 – Changing the Batteries (Receiver)
2. Install six new AA alkaline batteries (LR6),
observing correct polarity as indicated
in the battery compartment.
3. Securely reinstall the battery compart-
ment cover.

Pre-Operation Inspection

WARNING
Daily before use, inspect your A-Frame
999-995-095.10_REV. A
Battery Compartment
-
+
-
-
+
Cover
Battery
Compartment Cover
A-Frame Fault Locator
Fault Locator and correct any problems
to reduce the risk of serious injury from
electric shock and other causes, and
prevent equipment damage.
1. Make sure the transmitter and receiver
units are OFF.
2. Remove the batteries and inspect for
signs of damage. Replace if necessary.
Do not use if the batteries are damaged.
3. Clean the equipment. This aids inspection
and helps prevent the tool from slipping
from your grip.
4. Inspect the locator for the following:
• Proper assembly, maintenance and com -
pleteness.
• Any broken, worn or missing parts.
• Inspect the transmitter test leads for
damaged insulation or exposed wire.
• Presence and readability of the transmit-
ter and receiver warning labels (Figure
2 and 4).
• Any other condition which may prevent
safe and normal operation.
If any problems are found, do not use
the A-Frame Fault Locator until the prob-
lems have been repaired.
5. Inspect and maintain any other equip-
ment being used per its instructions to
make sure it is functioning properly.
Set-Up And Operation
Instructions
WARNING
Do not connect to live voltage or active
utility lines. Disconnect the conductor
to be tested from any other service, com-
ponents, or anything that might be af-
fected by high voltage. De-energize any
circuits in or around the work area.
Always attach transmitter test leads be-
fore turning unit ON and turn unit OFF be-
fore disconnecting leads. This will re-
duce the risk of electrical shock.
Never turn transmitter ON the unit when
anyone is touching the conductor, ground
stake, or any part of the transmitter. Turn
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft-103Fr-30

Table of Contents