Cisco Firepower 4100 Series Hardware Installation Manual page 28

Hide thumbs Also See for Firepower 4100 Series:
Table of Contents

Advertisement

Hardware Specifications
Specification
Weight
Storage
SSD
MSP
Memory
DDR4 DIMM
Power
System power
Power supply
module
Redundant power
Environment
Temperature
Humidity
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide
24
4110
4120
36 lb (16kg) 2 power supply modules, 2 network modules, 6 fans
30 lb (13.6 kg) no power supply modules, no network modules, no fans
100 GB
The storage SSD must be
Note
installed in slot 1. Slot 2 is
reserved for the MSP SSD.
If you are running Firepower
Note
Threat Defense software, we
recommend that you upgrade to
the latest version (at least to
Version 6.1.0) to take
advantage of software updates
that enhance SSD management
performance and longevity.
800 GB
Note
The MSP SSD must be installed in slot 2,
64 GB
128 GB
AC: 100/240 V AC 10 A (at 100 V), 50 to 60 Hz
DC: -40 V DC to -60 V DC, 26 A (at -40 V)
AC or DC
Yes
Operating: 32° to 104° F (0° to 40° C)
Nonoperating: -40° to 149°F (-40° to 65°
C)
Operating and nonoperating: 5 to 95 % noncondensing
4140
4150
200 GB
The storage SSD must be
Note
installed in slot 1. Slot 2 is
reserved for the MSP SSD.
If you are running Firepower
Note
Threat Defense software, we
recommend that you upgrade to
the latest version (at least to
Version 6.1.0) to take
advantage of software updates
that enhance SSD management
performance and longevity.
256 GB
Operating: 32° to 95° F (0° to 35° C) at
sea level
1° C reduction of maximum for every 1000
ft (305 m) above sea level
Nonoperating: -40° to 149° F (-40° to 65°
C)
Overview

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents