This section describes how to change system settings.

Console Mode

displays an alpha/numeric keypad on the screen that can be used to make changes on the panel.
Console Mode
To access the
Console Mode
ICON
On the
Home
icon, and then enter an authorised code.

Set RS485 Address

Follow this procedure if you want to change the keypad's RS485 address in the panel.
ICON
1. On the
Home
then enter an authorised engineer code.
2. Press the

System Setup

3. Press the
Eng. Setup
4. Press the
RS485 Address
5. Use the up/down arrows to select a valid
address.
6. Press the
Apply

EN50131 Mode

The EN50131 compliance feature is part of a European Standard designed to prevent unauthorized users from viewing
the status of the security system. When
Follow this procedure if you want to enable/disable
ICON
1. On the
Home
then enter an authorised engineer code.
2. Press the
System Setup
3. Press the
Eng. Setup
4. Press the
Options
5. Select/deselect
6. Press the
Apply
System Setup
:
ACTION
screen, press the
Console Mode
ACTION
screen, press the
Setup
icon, and
icon.
icon.
icon.
icon.
is turned on the status bar is not displayed on the
EN50131 Mode
EN50131 Mode
ACTION
screen, press the
icon, and
Setup
icon.
icon.
icon.
.
EN50131 Mode
icon.
:
19