Cisco SCE 2000 Installation And Configuration Manual page 83

4xgbe
Hide thumbs Also See for SCE 2000:
Table of Contents

Advertisement

Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
There are six topology-related parameters:
Connection mode — Can be either of the following, depending on the physical installation of the
SCE 2000.
Type of deployment — Can be one of the following, depending on the actual deployment:
Physically connected link (cascade topology only) — In a cascade topology, the user must assign
an index to each of the links. This index is used to identify the services per link.
Priority (cascade topology only) — In a cascade topology, this parameter determines which SCE
2000 is chosen as the active SCE 2000 in the "active election" procedure. This decision is taken only
when both SCE 2000s are starting up together. If there is one working SCE 2000 and the other is
just starting up, then the working one will automatically be chosen as active and the other one as
standby. This parameter can be set to one of the following:
On-Failure behavior — Determines the behavior of the SCE 2000 upon failure, or reboot. One of
the following link modes may be chosen for the SCE 2000 in the cases of failure or reboot.
Admin status after abnormal reboot — This parameter determines whether the SCE 2000 returns
to full operational mode after abnormal (not user-requested) boot, or stays in non-operational mode,
in which the SCE 2000 behaves as in failure mode. This parameter can be set to one of the following:
The procedure described below is a presentation of all the questions in the topology configuration. In
actual practice, all questions may not be presented for a particular configuration, depending on the
topology deployed.
Study the examples that follow to understand the procedure for various topologies.
OL-7824-07
Inline
Receive-only
Single-SCE Platform — a single SCE 2000 is deployed on one or two GBE links
Cascade — two cascaded SCE 2000s are deployed on two GBE links, working as a fully .
In a single-SCE platform deployment, the indices of the links cannot be changed by the user and
are:
link-0 — the link connected to ports 1 and 2
link-1 — the link connected to ports 3 and 4
In a cascade deployment, the user must define which link is connected to which SCE 2000. The
index must be different for each SCE 2000. In this case the user can choose one of the following:
Link-0 — the link connected to this SCE 2000 is identified as 0.
Link-1 — the link connected to this SCE 2000 is identified as 1.
Primary
Secondary
Bypass — traffic is bypassed using the internal bypass card.
Cutoff — the link is forced down.
Operational
Non-operational
Cisco SCE 2000 4xGBE Installation and Configuration Guide
Initial System Configuration
5-19

Advertisement

Table of Contents
loading

Table of Contents