Cisco catalyst 6500 series Configuration Note page 84

Content switching module
Hide thumbs Also See for catalyst 6500 series:
Table of Contents

Advertisement

Configuring Fault Tolerance
Command
Step 5
Router(config-slb-vserver)# virtual
192.158.38.30 tcp www
Step 6
Router(config-module-csm)# inservice
Step 7
Router(config-module-csm)# vlan 3 server
Step 8
Router(config-slb-vlan-server)# ip addr
192.158.39.10 255.255.255.0
Step 9
Router(config-slb-vlan-server)# alias ip
addr 192.158.39.20 255.255.255.0
Step 10
Router(config-slb-vlan-server) vlan 9
Step 11
Router(config-module-csm)# ft group
ft-group-number vlan 9
Step 12
Router(config-module-csm)# vlan
Step 13
Router(vlan)# vlan 2
Step 14
Router(vlan)# vlan 3
Step 15
Router(vlan)# vlan 9
Step 16
Router(vlan)# exit
1.
Enter the exit command to leave a mode or submode. Enter the end command to return to the menu's top level.
2.
The no form of this command restores the defaults.
To configure the standby (B) CSM for fault tolerance, perform this task (see
Command
Step 1
Router(config-module-csm)# vlan 2 client
Step 2
Router(config-slb-vlan-client)# ip addr
192.158.38.40 255.255.255.0
Step 3
Router(config-slb-vlan-client)# gateway
192.158.38.20
Step 4
Router(config-module-csm)# vserver vip1
Step 5
Router(config-slb-vserver)# virtual
192.158.38.30 tcp www
Step 6
Router(config-module-csm)# inservice
Step 7
Router(config-module-csm)# vlan 3 server
Step 8
Router(config-slb-vserver)# ip addr
192.158.39.30 255.255.255.0
Step 9
Router(config-slb-vserver)# alias
192.158.39.20 255.255.255.0
Step 10
Router(config-module-csm) vlan 9
Catalyst 6500 Series Content Switching Module Configuration Note
7-4
Chapter 7
Configuring Redundant Connections
Purpose
Creates a virtual IP address.
Enables the server.
Creates the server-side VLAN 3 and enters the SLB
VLAN mode.
Assigns the CSM IP address on VLAN 3.
Assigns the default route for VLAN 3.
Defines VLAN 9 as a fault-tolerant VLAN.
Creates the content switching active and standby
(A/B) group VLAN 9.
1
Enters the VLAN mode
.
Configures a client-side VLAN 2
Configures a server-side VLAN 3.
Configures a fault-tolerant VLAN 9.
Enters the exit command to have the configuration
take affect.
Purpose
Creates the client-side VLAN 2 and enters the
1
SLB VLAN mode
.
Assigns the content switching IP address on
VLAN 2.
Defines the client-side VLAN gateway.
Creates a virtual server and enters the SLB
virtual server mode.
Creates a virtual IP address.
Enables the server.
Creates the server-side VLAN 3 and enters the
SLB VLAN mode.
Assigns the CSM IP address on VLAN 3.
Assigns the default route for VLAN 2.
Defines VLAN 9 as a fault-tolerant VLAN.
2
.
Figure
7-1):
OL-4612-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6000 series

Table of Contents