Cisco catalyst 6500 series Configuration Note page 141

Content switching module
Hide thumbs Also See for catalyst 6500 series:
Table of Contents

Advertisement

Chapter 11
Configuring Firewall Load Balancing
3.
VLAN 104 provides a connection through Firewall 2 to CSM A.
4.
VLAN 200 provides the connection to the internal network.
Configuring VLANs on CSM B
To configure the three VLANs, perform this task:
Command
Step 1
Switch-B(config)# module csm 6
Step 2
Switch-B(config-module-csm)# vlan 102
server
Step 3
Switch-B(config-slb-vlan-server)# ip
address 10.0.101.36 255.255.255.0
Step 4
Switch-B(config-slb-vlan-server)# alias
10.0.101.200 255.255.255.0
Step 5
Switch-B(config-slb-vlan-server)# exit
Step 6
Switch-B(config-module-csm)# vlan 104
server
Step 7
Switch-B(config-slb-vlan-server)# ip
address 10.0.102.36 255.255.255.0
Step 8
Switch-B(config-slb-vlan)# alias
10.0.102.200 255.255.255.0
Step 9
Switch-B(config-slb-vlan-server)# exit
Step 10
Switch-B(config-module-csm)# vlan 20
server
Step 11
Switch-B(config-slb-vlan-server)# ip
address 10.1.0.36 255.255.255.0
1.
This step provides a target for CSM A to use in making a load-balancing decision.
Configuring Server Farms on CSM B
To configure three server farms on CSM B, perform this task:
Note
OL-4612-01
SERVERS-SF specifies that client NAT will be performed using a pool of client NAT addresses
that are created earlier in the example using the natpool command. You must create the NAT
pool before referencing the command.
Purpose
Enters multiple module configuration mode and
specifies that CSM B is installed in slot 6.
Specifies VLAN 102 as the VLAN that is being
configured, identifies it as a server VLAN, and
enters VLAN configuration mode.
Specifies an IP address and netmask for VLAN 102.
Specifies an alias IP address and netmask for VLAN
1
102
.
Returns to multiple module configuration mode.
Specifies VLAN 104 as the VLAN that is being
configured, identifies it as a server VLAN, and
enters VLAN configuration mode.
Specifies an IP address and netmask for VLAN 104.
Specifies an alias IP address and netmask for VLAN
1
104
.
Returns to multiple module configuration mode.
Specifies VLAN 20 as the VLAN that is being
configured, identifies it as a server VLAN, and
enters VLAN configuration mode.
Specifies an IP address and netmask for VLAN 20.
Catalyst 6500 Series Content Switching Module Configuration Note
Configuring Stealth Firewall Load Balancing
11-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6000 series

Table of Contents