System Messages
Error Message SLB-DIAG: WatchDog task not responding.
SLB-DIAG: Fatal Diagnostic Error %x, Info %x.
SLB-DIAG: Diagnostic Warning %x, Info %x.
Explanation
Recommended Action
Error Message SLB-FT: Heartbeat intervals are not identical between ft pair.
SLB-FT: heartbeat interval is identical again
SLB-FT: The configurations are not identical between the members of the fault
tolerant pair.
Explanation
modules.
Recommended Action
farm configurations.
Error Message SLB-FT: Standby is not monitoring active now.
Explanation
two versions of the CSM. The standby CSM stays as standby and does not take over as active if the
primary CSM fails.
Recommended Action
Catalyst 6500 Series Content Switching Module Configuration Note
B-4
Various diagnostic problems were encountered during the board boot procedure.
Check for a CSM hardware failure or corrupted software in the Flash memory.
These errors occur as a result of a misconfiguration between two redundant CSM
Check the fault-tolerant configuration attributes and the real server and server
This problem is the result of a version mismatch of the fault tolerance protocol between
The CSM does not support hitless (HA) upgrades in this situation.
Appendix B
Troubleshooting and System Messages