2-Port Channelized Oc-12/Ds0 Spa Interface Specifications; 2-Port Channelized Oc-12/Ds0 Spa Sfp Optical Transceiver Modules And Cables - Cisco 10000 SIP-600 Installation Manual

10000 series router sip and spa hardware
Table of Contents

Advertisement

2-Port Channelized OC-12/DS0 SPA
Table 3-17
LED Label
CAR
ACT
STATUS
1. CAR and ACT LEDs are per port
2. STATUS LED is per SPA

2-Port Channelized OC-12/DS0 SPA Interface Specifications

The framer processes incoming and outgoing SONET frames. The framer operates at OC-12c/STM-4
line rates (622.08 Mbps). Packet data is transported with a user-configured encapsulation (such as
Point-to-Point Protocol [PPP]) and mapped into the STS-12c/STM-4 frame.
The 2-Port Channelized OC-12/DS0 SPA interface is compliant with ANSI and Telco standards. The
interface provides support for Management Information Base (MIB) RFC 3592, RFC 2558, RFC 3896,
and RFC 2496.
2-Port Channelized OC-12/DS0 SPA SFP Optical Transceiver Modules and
Cables
The 2-Port Channelized OC-12/DS0 SPA uses a small form-factor pluggable (SFP) optical transceiver
module installed in each port for SONET single-mode and multimode optical fiber connection (see
Figure
Cisco Systems qualifies the optics that are approved for use with its SPAs. The 2-Port Channelized
OC-12/DS0 SPA supports the following types of optical transceiver modules:
Cisco 10000 Series Router SIP and SPA Hardware Installation Guide
3-32
2-Port Channelized OC-12/DS0 SPA LEDs
Color
State
1
Off
Off
Green
On
Amber
On
Off
Off
Green
On
Amber
On
2
Off
Off
Green
On
Amber
On
3-9).
Multimode (MM) SFP module—SFP-OC12-MM
Short reach (SR) SFP module—SFP-OC12-SR
Intermediate reach (IR) SFP module (15 km)—SFP-OC12-IR1
Long reach (LR) SFP module (40 km)—SFP-OC12-LR1
LR SFP module (80 km)—SFP-OC12-LR2
Chapter 3
Cisco 10000 Series Router Shared Port Adapters
Meaning
Port is not enabled by software.
Port is enabled by software, and there is a valid SONET signal
without any alarms.
Port is enabled by software, and there is at least one alarm.
Port is not enabled by software.
Port is enabled by software, loopback is off.
Port is enabled by software, loopback is on.
SPA power is off.
SPA is ready and operational.
SPA power is on and SPA is being configured.
OL-13838-02