CAUTION
Be certain to dress the wires properly to ensure cabling does not contact switches 1-2 on the back of
the POD.
Do not force the POD into the enclosure as it may indicate an interference condition resulting in
damage to the wiring, POD or switch settings.
Sensor Mounted to
Remote Sensor Kit
NOTE:
Refer to control drawing 3000E3159 for installation requirements for EC
cells and remote mounting.
XNX Universal Transmitter Quick Start Guide
HART
Adaptor
EC
Adaptor
Sensor Cartridge
Local Sensor Mounted to Transmitter
Sensor Retainer
Weatherproof Cap
Figure 10. EC personality wiring
Optional Local HART
IS Barrier must
be connected to J1
S1 S2
J1 HART
1
2
3
4
+
5
-
6
J2 EC Barrier
EC IS Barrier must
be connected to J2
EC IS Barrier
Sensor Cartridge
Sensor Retainer
Weatherproof Cap
FOR FM COMPLIANCE, THE SUPPLIED TAG
WITH XNXXSH1FM, XNXXSC1FM, AND
XNXSO1FM CARTRDIGES MUST BE
ATTACHED TO THE TRANSMITTER OR
REMOTE MOUNT KIT WHERE INSTALLED.