5.3.4 DT-5023BAT/DT-5025LBAT
Table 5.16
Item
Resistance to vibration
Resistance to vibration
(in carton box)
Resistance to impact
In bare condition
In individual carton box
5.3.5 DT-894CFU (CF Card Extension Unit)
Table 5.17
Item
Resistance to vibration
Resistance to impact
In bare condition
In individual carton box
In master carton box
Specification
1 G
2 G
75 cm
75 cm or less
Specification
0.15 G or less
10 to 55 Hz
In X,Y, and Z directions
Reciprocally for 30
minutes
The unit is installed on
the DT-X10.
120 cm
3 times of each faces (6
faces) and corner (4
corners) onto concrete
surface
40 cm
1 time of each faces (6
faces) and corner (4
corners) onto lauan wood
surface
70 cm or less
1 time of each face (6 faces), corner (1 ) and edge (3
edges)
50 cm or less
35
Condition
10 to 55 Hz
In X,Y, and Z directions
Reciprocally for 30 minutes
10 to 55 Hz
In X,Y, and Z directions
Reciprocally for 30 minutes
6 faces, 1 corner and 3 edges onto P tile.
6 faces, 1 corner and 3 edges onto P tile.
Condition
With the extension unit
installed on the terminal
With the standard size
card cover installed on the
terminal.
With the large-sized card
cover installed on the
terminal.