Sony DVS-9000 User Manual page 576

With ccp-8000 series center control panel
Hide thumbs Also See for DVS-9000:
Table of Contents

Advertisement

2
3
4
5
6
576
DME Special Effect Operations
In the <Mask> group, press the button for the group of the effect to which
you want to apply the mask, turning it on.
Effect Gp 1: Posterization, Solarization, Nega, Sepia, Mono, Contrast,
Mosaic, Sketch, Metal
Effect Gp 2: Defocus, Blur, Glow
Note
On the MVE-8000A, Effect Gp 1 and Effect Gp 2 cannot be turned on at
the same time.
Press [Position/Size].
Set the mask source parameters.
The valid ranges of the parameter values depend on the aspect ratio (4:3/
16:9) selected in the system, as follows.
• 4:3 mode
Knob
Parameter
Adjustment
1
H
Horizontal position
2
V
Vertical position
3
Size
Size of mask
4
Soft
Softness of mask
5
Pattern
Pattern number
a) This setting value is not supported on the MVE-8000A.
• 16:9 mode
Knob
Parameter
Adjustment
1
H
Horizontal position
2
V
Vertical position
3
Size
Size of mask
4
Soft
Softness of mask
5
Pattern
Pattern number
a) This setting value is not supported on the MVE-8000A.
To invert the mask source, press [Invert], turning it on.
As required, set the modifiers for the mask pattern.
Setting values
–8.00 to +8.00
–6.00 to +6.00
0.00 to 100.00
0.00 to 100.00
a)
21, 24, 304
Setting values
–8.00 to +8.00
–4.50 to +4.50
0.00 to 100.00
0.00 to 100.00
a)
21, 24, 304