Program 14 : Trunk, Basic Setup; Basic Trunk Data Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Level:
IN
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to the
table below for a description of each option, its range and default setting.
Input Data
Trunk Port Number
Item
Item
No.
01
Trunk Name
Set the names for trunks. The
trunk name displays on a
multiline terminal for incoming
and outgoing calls.
02
Transmit Level
Select the CODEC gain for the
trunk. The option sets the gain
(signal amplification) for the trunk
you are programming.
03
Receive Level
Select the CODEC gain for the
trunk. The option sets the gain
(signal amplification) for the trunk
you are programming.
04
Transmit Gain Level for
Conference and Transfer Calls
Select the CODEC gain type
used by the trunk when it is part
of an Unsupervised Conference.
05
Receive Gain Level for
Conference and Transfer Calls
Select the CODEC gain type
used by the trunk when it is part
of an Unsupervised Conference.
SV9100 Programming Manual

Program 14 : Trunk, Basic Setup

14-01 : Basic Trunk Data Setup

Input Data
Up to 12 Characters
1~57
(-15.5dB~+12.5dB in 0.5dB intervals)
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
Program:
001~400
Default
Line 001
Line 002
Line 003
:
Line 400
32 (0dB)
32 (0dB)
32 (0dB)
16 (-8dB)