The Wireless Relay Box
in a Connected Pack
is bound as a boiler
controller. If you intend
to use it as a Zone Valve
controller the binding
must be cleared from
the Wireless Relay Box
first.
evohome Installation Guide
To bind the Room Temperature
Sensor (HCW82 or HCF82)
Press the bind button on the bottom right hand corner
1
of the unit once. The red LED light will flash
You should receive a SUCCESS message on the
2
evohome Controller (if not go back and re-bind)
1
Then, on the Wireless Relay Box (BDR91)
Press and hold the button for 15 seconds (until the red
1
LED blinks rapidly) to clear any previous binding data
Press and hold the button again for 5 seconds
2
(until the red LED blinks slowly)
On the evohome Controller press
3
the green bind button
You should receive a SUCCESS message on the
4
evohome Controller (if not go back and re-bind)
1