Before performing any of the
following special functions, the
programming mode of the controller
needs to be accessed. See
"Accessing the programming level".
^ Access the programming level E02 of
the controller (see "Accessing the
programming level").
Set the dosage concentration
according to the detergent
manufacturer's recommendations.
Example:
The manufacturer recommends a
detergent concentration of 0.5%.
The value to be set is 0.50.
^ Turn the program selector to
"Inorganica". The display shows
either the dosage time in seconds
(for powdered detergent) or the set
dosage concentration in % (for liquid
detergent).
"10" = Dosage time of 10 seconds for
powdered detergent, or
"0.10" - "0.80" = 0.1 % - 0.8 %
concentration for liquid detergent
dosage.
^ Press and hold "Display" ß until the
desired value appears.
^ Please note the dosage setting here:
^ Press the "Display" ß button.
The dosage system will be primed
automatically. The priming is done if
the display shows "0".
35