B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.3.1
Configurations
Configuration parameters
As it is possible to freely combine hardware components, it is necessary to inform the
system which components are combined and in what manner. On the HMI Advanced, this is
done by means of an operator dialog in the commissioning area. In the case of the HMI
Embedded/OP030, the configuration parameters are entered through the creation of a
configuration file which is loaded for commissioning. The file must be structured as described
below.
Figure 2-14
Examples
For complete examples of configuration files, please refer to Section "Examples" in this
description.
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
2.3 Several operator panel fronts and NCUs, standard functionality
Structure of configuration file NETNAMES.INI
131